Find Passenger Lift, Passenger Elevator, Home Lift on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Vvvf Driver Electrical Passenger Elevator Machine
Home > Products > Passenger Elevator > Vvvf Driver Electrical Passenger Elevator Machine

Vvvf Driver Electrical Passenger Elevator Machine

    Payment Type: L/C, T/T, Western Union, Money Gram, Cash
    Productivity: 1, 000 PCS/Year
    Place of Origin:  Dongguan City, Guangdong Province, China
    Supply Ability: 1, 000 PCS/Year

Basic Info

Model No.:  DEEOO-522

Product Description

Model NO.: DEEOO-522 Capacity: 500-1000kg Speed: 1.00 - 2.00m/s Position of Computer Room: up Door Knife: Double Attendant: Without Attendant Trademark: DEEOO Origin: Dongguan City, Guangdong Province, China Driving Type: AC Elevator Persons: 6 - 10 Control Mode: Collective Selective Control Elevator Door: Center Opening Door Deceleration Device: With Deceleration Device Elevator Type: Passenger Elevator Machine Specification: SGS HS Code: 8428101090 Electrical Elevator with VVVF Driver

The Passenger Lift has the following 11 advantages,

1. Energy Saving, Environment Protection; 2. Space saving 60%-100%;

3. Variable-Frequency System; 4. Safe and Reliable;

5. Safe door protection device; 6. Digital loading controller;

7. Intelligent IC card management system; 8. Serial communication system;

9. Intelligent elevator door machine inverter; 10. Personality group control management;

11. Modular computer control system can improve 25% more efficiency.

The product's parameter information is as following.
No. Item Description Remarks
1 Car Roof Decoration 427  
2 Car side and Car back Center board is made of mirror finish,etching finish,hairline finish,vibration finish , concave in golden.  Auxiliary board is made of  hairline finish ,etching finish , vibration finish and concave in golden .  
3 Handrail 313F  
4 Car Floor Decoration PVC floor  
  No. Function code and name     Function description           1     FCL Full collection selective     After implementing the comprehensive analysis and judgement to the upper and lower call signal in the building,floor    
 selecting instruction and all other signals , the lift will automatically select the signal that is in line with the running     
direction of the lift , to conduct response in order .      2     LNS Full-load bypass     When the load in the car reaches the default value of being fully loaded , the lift will be in fully loaded direct operation     
status  and will not answer the call outside the car , but directly give out response to the instruction in the car to reach    
 the specified floor .     3     RIN Reinitialization travel     When it is powered on again after power interruption and its position signal is not reserved or the position of the car     
cannot be confirmed , the lift will go back to the end station to reset its position . After positioning , the position    
 indicator will show the floor where the car  is located , and the lift recovers to normal operation .     4     EN-CCO Auto opposite instruction deletion  When running upward or downward , the instruction that is opposite to the running direction can be deleted automa-    
tically .      5     CBC Cancel bug command     After the instruction is registered , the registered instruction can be deleted through continuously push down the     
button before the startup of the lift . After the lift is started up, the system will not allow the registered instruction    
 to be deleted , in order to protect the personnel security of the passenger .       6     REL Automatical relevelling     When the error of the plate threshold and the landing sills surpasses a certain value , which is caused by the load    
 change due to passengers's passing in and out , the lift will implement relevelling to make the car back to exact    
 leveling position . Remark : it is only applicable to lift with 2-2.5 m/s of speed and landing above 24 floors .     7     DOB/DCB Door open button lamp / Door     
close button      There is no micromatic button to control the opening and closing of the door on the car operation panel of the lift ,    
 in order that the passengers can smartly control the time of the door's opening and closing according to their     
demand .     8     DOBL/DCBL Door open button lamp / Door
close button lamp     When the opening or closing button is pushed down , the button lamp will be lighted to inform successful response .      9     CFT Waiting at dining hall     Set longer opening time for the floor where the dining hall is located in the building , so as to satisfy the extra     
passenger flow volume .      10   DDT Separate control of hall and car door    The statistics suggests that the waiting time for opening the door caused by the call outside the hall is longer     
than the waiting time for opening the door caused by the instruction in the car . The function can improve the     
whole operating efficiency efficiency of the lift by separately adjusting the holding time of opening the door when     
answering the call and the instruction .       11   CCM Car arrival time      Installed on the car roof , when it reaches the docking floor , the lift will give out a ringing sound to inform the     
passenger that he or she has reached the specified floor .     12   EN-CK Cancel door close waiting      In automatic mode , pushing down the button of closing the door can immediately close the door in advance ,    
 when the door is kept fully open and in the delaying period of opening the door .      13   HPS Self-learning of hoistway position      It has the self-teaching function to the hoistway positon , and can store the hoistway positon signal, thus being    
 able to realize the direct docking when the lift is in normal operation .       14   ADO Door open in advance     When it is approaching the door region , the lift will open the door in advance and creep to the leveling position     
at low speed in case of being compliance with the security requirements . Remark:it is only applicable to lift with     
2~2.5 m/s of speed and landing above 24floors . In addition , it is optional function for 1.0~1.75 m/s .     15   SE Torque compensation when startup     In order to obtain more comfortable feeling when the lift is started up , the system will calculate the load in the     
car and optimize it by torque compensation when startup .       16   COR Recover operation     When the lift is powered on again after interruption , and is outside the leveling region , the door will be opened    
 automatically to recover normal operation . Remark : it is only applicable to lift with 2~2.5 m/s of speed and     
landing above 24floors .     17   SGS Infra-red multi-beam screen detector  
 and safety shoe protection     Provide the passengers with safety control by virtue of the double monitoring function of the reliable mechanical     
baffle and sensitive infrared beam .     18   RE-OP Hall out-opening door      In the process of closing the door , the door will be opened again when pushing down the homodromous call     
button outsides the hall and in the car .     19   LWS Overload protection      When the load of the car surpasses the rated load , the overloading buzzer will began pealing to inform overload .     
At the moment , the overload will be displayed , the car will not close its door and the lift will keep still .     20   OHT Driving arrangement overheat     When the temperature of the motor surpasses the default value , which is caused by the over high temperature     
in the machine room or the operation heating , the lift will automatically enter the protected mode . The lift will stop    
 at the nearby leveling , and open the door to evacuate the passengers and  shut down the lighting and fan in the car .     
When the temperature becomes normal , the lift will recover to normal operation .        21   NTSD Terminal floor protection     When the lift reaches the terminal floor and its speed does not reduce to the default value , the system will enforce     
the lift to slowdown , thus protecting its safe operation .      22   TCI Car roof overhauling     An overhauling box is installed on the car roof , which makes the maintenance safer and quicker .     23   ICU-5 Inter communication installation     In particular cases , keep the sound contact between the machine room and the monitoring center by the intercom    
 devices installed on the car operation panel , car roof and the platform . Remark : the cable from the machine room    
 to the monitoring center shall be supplied by the user .      24   DCP Delay closing protection      When the time of opening the door of the lift surpasses the default value due to the external call button being pusher     
down, the lift will force to close the door to answer other signals . When the door does not be closed tightly after     
repeated compelling door closing , the lift will stop and open the door , and the external and internal call signals will    
 be canceled automatically. When being monitored to be closed normally , the lift will recover to normal operation .      25   FD Fault self-diagnosis     When the control system automatically monitors the abnormal condition of the control circuit , the lift will automati_    
cally stop to protect the security of the passengers .       26   DTO Door opening protection     When the time that the lift cannot open the door in place surpasses the default value due to jammed machine , the    
 external and internal call signals will be canceled automatically , and the lift will travel to the adjacent floor and open     
the door to evacuate the passengers .     27   DTC Door closing protection     When the time that the lift cannot open the door in place surpasses the default value due to jammed machine , and    
 the closed signal has not been monitored after three times of repeated door closing , the lift will automatically enter    
 the protection mode , while , when the lift has monitored that the door has been closed normally , it will recover to     
normal operation .     28   UV Line filter monitoring function     With a certain period of time , if the voltage of the electric fence turns up continuous fluctuation , the system will give    
 out alarm automatically .      29   CSP  Door closing torque protection     The lift will reopen the door ,when reverse resistance works in the process of closing the door and the reverse resistance   
 surpasses the default torque value .       30   SPD FEEDBACK Speed feedback      Once the system monitors that the actual speed is not in line with the given speed , it will automatically cut off the     
security circuit and give out alarm .        31   CONT FEEDBACK Contactor feedback     No matter the lift is in standby mode or running mode ,  the system will detect and output the status of the contactor .     
Once the abnormal status of the contactor is detected, the system will halt the lift .     32   BRK FEEDBACK Brake feedback     Monitor the signal of the internal contraction brake delay for the entire process . When the actual status of the inter- nal     
contraction brake delay is monitored to be not in line with the given setting , the system will make the lift stop running .     33   LOBBY Auto return the base station     With regarding to single lift , the running base  station shall be set up according to the actual condition in the building .     
If there is no call or instruction registration within the default time , the car will automatically return to the base station ,    
 and open the door to enter the standby mode . The base station is often set up on the floor with large passenger flow or    
 the hall on the first floor .     34   ANS Anti-nuisance protection     In order to avoid idle load operation , the computer will conduct  logical judgement to the load volume and delete abnormal 
commands .This function can avoid mischief-making and error commands from the car .      35   ACP Anti-crime protection     When the function is started up , the lift will open the door to accept examination after passing the setting floor .       36   PRK Auto parking     When all lifts in the building are in stand-by mode , the lifts among the automatic operation group will automatically dock     
at the different floor,thus improving the response speed  of the lift group to call .      37   HPI-LED/CPI-LED Digital hall/car display     Momentarily display the landing in sixteen field number where the lift is located on the car operation panel and the hall call  
 box of each floor , in order that the passenger can easily know the operating status of the lift .     38   HDI/CDI Hall/car direction indication     In order to insure that the passenger can easily know the running direction of the lift , a arrow indicator light is set up on the 
car operation panel and the hall call panel to inform the running direction .       39   ELTU Car emergency lighting      The emergency lighting arrangement is installed in the car and it will start up when power failure .     40   BELL Car alarm bell     In emergency cases , the passenger can inform the outside by pushing down the alarm button in the car.       41   ERO Emergency electric operation in     
machine room     A set of emergency electric operating equipment is installed in the control cabinet in the machine room , which can provide 
aid to rescue in emergency cases .          

Contact us if you need more details on Elevator. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Passenger Elevator、Elevator Machine. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Passenger Elevator